Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.080
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-35805441

RESUMO

The SARS-CoV-2 virus, which is driving the current COVID-19 epidemic, has been detected in wastewater and is being utilized as a surveillance tool to establish an early warning system to aid in the management and prevention of future pandemics. qPCR is the method usually used to detect SARS-CoV-2 in wastewater. There has been no study using an immunoassay that is less laboratory-intensive than qPCR with a shorter turnaround time. Therefore, we aimed to evaluate the performance of an automated chemiluminescence enzyme immunoassay (CLEIA) for SARS-CoV-2 antigen in wastewater. The CLEIA assay achieved 100% sensitivity and 66.7% specificity in a field-captured wastewater sample compared to the gold standard RT-qPCR. Our early findings suggest that the SARS-CoV-2 antigen can be identified in wastewater samples using an automated CLEIA, reducing the turnaround time and improving the performance of SARS-CoV-2 wastewater monitoring during the pandemic.


Assuntos
COVID-19 , Técnicas Imunoenzimáticas , SARS-CoV-2 , Águas Residuárias , Antígenos Virais/imunologia , Antígenos Virais/isolamento & purificação , COVID-19/epidemiologia , COVID-19/prevenção & controle , Humanos , Técnicas Imunoenzimáticas/métodos , Medições Luminescentes , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Águas Residuárias/virologia , Vigilância Epidemiológica Baseada em Águas Residuárias
4.
Nat Methods ; 19(4): 449-460, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35396484

RESUMO

Deciphering immune recognition is critical for understanding a broad range of diseases and for the development of effective vaccines and immunotherapies. Efforts to do so are limited by a lack of technologies capable of simultaneously capturing the complexity of adaptive immunoreceptor repertoires and the landscape of potential antigens. To address this, we present receptor-antigen pairing by targeted retroviruses, which combines viral pseudotyping and molecular engineering approaches to enable one-pot library-on-library interaction screens by displaying antigens on the surface of lentiviruses and encoding their identity in the viral genome. Antigen-specific viral infection of cell lines expressing human T or B cell receptors allows readout of both antigen and receptor identities via single-cell sequencing. The resulting system is modular, scalable and compatible with any cell type. These techniques provide a suite of tools for targeted viral entry, molecular engineering and interaction screens with broad potential applications.


Assuntos
Antígenos Virais , Lentivirus , Internalização do Vírus , Antígenos , Antígenos Virais/imunologia , Antígenos Virais/isolamento & purificação , Humanos , Imunoterapia/métodos , Lentivirus/imunologia , Receptores de Antígenos de Linfócitos B/imunologia , Receptores de Antígenos de Linfócitos T/genética , Receptores de Antígenos de Linfócitos T/imunologia
5.
PLoS Negl Trop Dis ; 16(2): e0010152, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35120141

RESUMO

BACKGROUND: Chikungunya virus (CHIKV) causes febrile illnesses and has always been misdiagnosed as other viral infections, such as dengue and Zika; thus, a laboratory test is needed. Serological tests are commonly used to diagnose CHIKV infection, but their accuracy is questionable due to varying degrees of reported sensitivities and specificities. Herein, we conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of serological tests currently available for CHIKV. METHODOLOGY AND PRINCIPAL FINDINGS: A literature search was performed in PubMed, CINAHL Complete, and Scopus databases from the 1st December 2020 until 22nd April 2021. Studies reporting sensitivity and specificity of serological tests against CHIKV that used whole blood, serum, or plasma were included. QUADAS-2 tool was used to assess the risk of bias and applicability, while R software was used for statistical analyses. Thirty-five studies were included in this meta-analysis; 72 index test data were extracted and analysed. Rapid and ELISA-based antigen tests had a pooled sensitivity of 85.8% and 82.2%, respectively, and a pooled specificity of 96.1% and 96.0%, respectively. According to our meta-analysis, antigen detection tests serve as a good diagnostic test for acute-phase samples. The IgM detection tests had more than 90% diagnostic accuracy for ELISA-based tests, immunofluorescence assays, in-house developed tests, and samples collected after seven days of symptom onset. Conversely, low sensitivity was found for the IgM rapid test (42.3%), commercial test (78.6%), and for samples collected less than seven of symptom onset (26.2%). Although IgM antibodies start to develop on day 2 of CHIKV infection, our meta-analysis revealed that the IgM detection test is not recommended for acute-phase samples. The diagnostic performance of the IgG detection tests was more than 93% regardless of the test formats and whether the test was commercially available or developed in-house. The use of samples collected after seven days of symptom onset for the IgG detection test suggests that IgG antibodies can be detected in the convalescent-phase samples. Additionally, we evaluated commercial IgM and IgG tests for CHIKV and found that ELISA-based and IFA commercial tests manufactured by Euroimmun (Lübeck, Germany), Abcam (Cambridge, UK), and Inbios (Seattle, WA) had diagnostic accuracy of above 90%, which was similar to the manufacturers' claim. CONCLUSION: Based on our meta-analysis, antigen or antibody-based serological tests can be used to diagnose CHIKV reliably, depending on the time of sample collection. The antigen detection tests serve as a good diagnostic test for samples collected during the acute phase (≤7 days post symptom onset) of CHIKV infection. Likewise, IgM and IgG detection tests can be used for samples collected in the convalescent phase (>7 days post symptom onset). In correlation to the clinical presentation of the patients, the combination of the IgM and IgG tests can differentiate recent and past infections.


Assuntos
Antígenos Virais/isolamento & purificação , Febre de Chikungunya/diagnóstico , Testes Sorológicos/normas , Antígenos Virais/sangue , Vírus Chikungunya/imunologia , Vírus Chikungunya/isolamento & purificação , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Sensibilidade e Especificidade
6.
Lancet ; 399(10326): 757-768, 2022 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-34942102

RESUMO

Diagnostics have proven to be crucial to the COVID-19 pandemic response. There are three major methods for the detection of SARS-CoV-2 infection and their role has evolved during the course of the pandemic. Molecular tests such as PCR are highly sensitive and specific at detecting viral RNA, and are recommended by WHO for confirming diagnosis in individuals who are symptomatic and for activating public health measures. Antigen rapid detection tests detect viral proteins and, although they are less sensitive than molecular tests, have the advantages of being easier to do, giving a faster time to result, of being lower cost, and able to detect infection in those who are most likely to be at risk of transmitting the virus to others. Antigen rapid detection tests can be used as a public health tool for screening individuals at enhanced risk of infection, to protect people who are clinically vulnerable, to ensure safe travel and the resumption of schooling and social activities, and to enable economic recovery. With vaccine roll-out, antibody tests (which detect the host's response to infection or vaccination) can be useful surveillance tools to inform public policy, but should not be used to provide proof of immunity, as the correlates of protection remain unclear. All three types of COVID-19 test continue to have a crucial role in the transition from pandemic response to pandemic control.


Assuntos
Teste para COVID-19/tendências , COVID-19/diagnóstico , Controle de Doenças Transmissíveis/organização & administração , Programas de Rastreamento/organização & administração , Pandemias/prevenção & controle , Anticorpos Antivirais/sangue , Antígenos Virais/isolamento & purificação , COVID-19/epidemiologia , COVID-19/transmissão , COVID-19/virologia , Teste para COVID-19/métodos , Vacinas contra COVID-19/administração & dosagem , Controle de Doenças Transmissíveis/métodos , Controle de Doenças Transmissíveis/tendências , Humanos , Programas de Rastreamento/tendências , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação
7.
Biosensors (Basel) ; 11(12)2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34940267

RESUMO

The current COVID-19 pandemic has increased the demand for pathogen detection methods that combine low detection limits with rapid results. Despite the significant progress in methods and devices for nucleic acid amplification, immunochemical methods are still preferred for mass testing without specialized laboratories and highly qualified personnel. The most widely used immunoassays are microplate enzyme-linked immunosorbent assay (ELISA) with photometric detection and lateral flow immunoassay (LFIA) with visual results assessment. However, the disadvantage of ELISA is its considerable duration, and that of LFIA is its low sensitivity. In this study, the modified LFIA of a specific antigen of the causative agent of COVID-19, spike receptor-binding domain, was developed and characterized. This modified LFIA includes the use of gold nanoparticles with immobilized antibodies and 4-mercaptobenzoic acid as surface-enhanced Raman scattering (SERS) nanotag and registration of the nanotag binding by SERS spectrometry. To enhance the sensitivity of LFIA-SERS analysis, we determined the optimal compositions of SERS nanotags and membranes used in LFIA. For benchmark comparison, ELISA and conventional colorimetric LFIA were used with the same immune reagents. The proposed method combines a low detection limit of 0.1 ng/mL (at 0.4 ng/mL for ELISA and 1 ng/mL for qualitative LFIA) with a short assay time equal to 20 min (at 3.5 h for ELISA and 15 min for LFIA). The results obtained demonstrate the promise of using the SERS effects in membrane immuno-analytical systems.


Assuntos
Teste para COVID-19/métodos , COVID-19 , Imunoensaio , Nanopartículas Metálicas , Análise Espectral Raman , Antígenos Virais/isolamento & purificação , COVID-19/diagnóstico , Ouro , Humanos , SARS-CoV-2
8.
Anal Bioanal Chem ; 413(29): 7251-7263, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34622322

RESUMO

Supply shortage for the development and production of preventive, therapeutic, and diagnosis tools during the COVID-19 pandemic is an important issue affecting the wealthy and poor nations alike. Antibodies and antigens are especially needed for the production of immunological-based testing tools such as point-of-care tests. Here, we propose a simple and quick magnetic nanoparticle (MNP)-based separation/isolation approach for the repurposing of infected human samples to produce specific antibodies and antigen cocktails. Initially, an antibody cocktail was purified from serums via precipitation and immunoaffinity chromatography. Purified antibodies were conjugated onto MNPs and used as an affinity matrix to separate antigens. The characterization process was performed by ELISA, SDS-PAGE, electrochemistry, isothermal titration calorimetry, and LC-Q-TOF-MS/MS analyses. The MNP-separated peptides can be used for mass spectrometry-based as well as paper-based lateral flow assay diagnostic. The exploitation of the current workflow for the development of efficient diagnostic tools, specific treatments, and fundamental research can significantly impact the present or eventual pandemic. This workflow can be considered as a two birds, one stone-like strategy.


Assuntos
Anticorpos Antivirais/isolamento & purificação , Antígenos Virais/isolamento & purificação , COVID-19/diagnóstico , Análise Custo-Benefício , Imunoensaio/economia , SARS-CoV-2/isolamento & purificação , Viremia/virologia , Anticorpos Antivirais/sangue , Antígenos Virais/sangue , COVID-19/virologia , Calorimetria , Eletroforese em Gel de Poliacrilamida , Ensaio de Imunoadsorção Enzimática , Humanos , SARS-CoV-2/imunologia , Manejo de Espécimes , Espectrometria de Massas em Tandem , Viremia/sangue , Fluxo de Trabalho
9.
Sci Rep ; 11(1): 20143, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34635788

RESUMO

Rapid, high-throughput diagnostic tests are essential to decelerate the spread of the novel coronavirus disease 2019 (COVID-19) pandemic. While RT-PCR tests performed in centralized laboratories remain the gold standard, rapid point-of-care antigen tests might provide faster results. However, they are associated with markedly reduced sensitivity. Bedside breath gas analysis of volatile organic compounds detected by ion mobility spectrometry (IMS) may enable a quick and sensitive point-of-care testing alternative. In this proof-of-concept study, we investigated whether gas analysis by IMS can discriminate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from other respiratory viruses in an experimental set-up. Repeated gas analyses of air samples collected from the headspace of virus-infected in vitro cultures were performed for 5 days. A three-step decision tree using the intensities of four spectrometry peaks correlating to unidentified volatile organic compounds allowed the correct classification of SARS-CoV-2, human coronavirus-NL63, and influenza A virus H1N1 without misassignment when the calculation was performed with data 3 days post infection. The forward selection assignment model allowed the identification of SARS-CoV-2 with high sensitivity and specificity, with only one of 231 measurements (0.43%) being misclassified. Thus, volatile organic compound analysis by IMS allows highly accurate differentiation of SARS-CoV-2 from other respiratory viruses in an experimental set-up, supporting further research and evaluation in clinical studies.


Assuntos
Antígenos Virais/isolamento & purificação , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Testes Imediatos , SARS-CoV-2/isolamento & purificação , Animais , COVID-19/imunologia , COVID-19/virologia , Teste Sorológico para COVID-19/instrumentação , Chlorocebus aethiops , Coronavirus Humano NL63/imunologia , Coronavirus Humano NL63/isolamento & purificação , Diagnóstico Diferencial , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Humanos , Vírus da Influenza A Subtipo H1N1/imunologia , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Espectrometria de Mobilidade Iônica , Estudo de Prova de Conceito , SARS-CoV-2/imunologia , Células Vero
10.
Artigo em Inglês | MEDLINE | ID: mdl-34493606

RESUMO

BACKGROUND AND OBJECTIVES: Varicella zoster virus (VZV) antigen has been detected in temporal arteries (TAs) of individuals with giant cell arteritis (GCA), the most common systemic vasculitis in older adults. Thus, we explored the contribution of VZV to GCA pathogenesis. METHODS: Formalin-fixed, paraffin-embedded TA sections from biopsy-positive GCA participants with VZV antigen (GCA/VZV-positive; n = 20) and without (GCA/VZV-negative, n = 20) and from normal participants with VZV antigen (control/VZV-positive, n = 11) and without (control/VZV-negative, n = 20) were analyzed by targeted RNA sequencing of the whole human transcriptome (BioSpyder TempO-Seq). Ingenuity pathway analysis and R-computational program were used to identify differentially expressed genes and pathways between groups. RESULTS: Compared with control/VZV-negative TAs, GCA/VZV-negative and GCA/VZV-positive TAs were significantly enriched for human transcripts specific for pathways involved in viral infections, including viral entry, nuclear factor kappa B activation by viruses, and other pathogen-related immune activation pathways. Similarly, human gene sets supporting viral infection were found in control/VZV-positive TAs that showed no morphological signs of inflammation, suggesting that the enriched pathways were not nonspecific signatures of infiltrating immune cells. All GCA TAs and control/VZV-positive TAs showed enrichment of transcripts involved in vascular remodeling, including smooth muscle cell migration. DISCUSSION: The detection of viral and immune activation pathways in GCA TAs supports a role for virus infection in GCA pathogenesis. In addition, the detection of viral pathways in control/VZV-positive TAs, along with vascular remodeling pathways, suggests that these samples may represent early infection with progression to clinical disease, depending on host and other environmental factors.


Assuntos
Antígenos Virais/isolamento & purificação , DNA Viral/isolamento & purificação , Arterite de Células Gigantes/virologia , Herpesvirus Humano 3 , Artérias Temporais/virologia , Idoso , Feminino , Formaldeído , Perfilação da Expressão Gênica , Arterite de Células Gigantes/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Inclusão em Parafina , Análise de Sequência de RNA , Artérias Temporais/patologia , Fixação de Tecidos
11.
Sci Rep ; 11(1): 17793, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34493744

RESUMO

The rapid identification and isolation of infected individuals remains a key strategy for controlling the spread of SARS-CoV-2. Frequent testing of populations to detect infection early in asymptomatic or presymptomatic individuals can be a powerful tool for intercepting transmission, especially when the viral prevalence is low. However, RT-PCR testing-the gold standard of SARS-CoV-2 diagnosis-is expensive, making regular testing of every individual unfeasible. Sample pooling is one approach to lowering costs. By combining samples and testing them in groups the number of tests required is reduced, substantially lowering costs. Here we report on the implementation of pooling strategies using 3-d and 4-d hypercubes to test a professional sports team in South Africa. We have shown that infected samples can be reliably detected in groups of 27 and 81, with minimal loss of assay sensitivity for samples with individual Ct values of up to 32. We report on the automation of sample pooling, using a liquid-handling robot and an automated web interface to identify positive samples. We conclude that hypercube pooling allows for the reliable RT-PCR detection of SARS-CoV-2 infection, at significantly lower costs than lateral flow antigen (LFA) tests.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Ensaios de Triagem em Larga Escala/métodos , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/métodos , Antígenos Virais/isolamento & purificação , Atletas , COVID-19/sangue , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/economia , Teste Sorológico para COVID-19/economia , Teste Sorológico para COVID-19/métodos , Redução de Custos , Ensaios de Triagem em Larga Escala/economia , Humanos , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , África do Sul , Manejo de Espécimes/economia , Medicina Esportiva/economia , Medicina Esportiva/métodos
12.
Vet Microbiol ; 262: 109243, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34563884

RESUMO

SARS-CoV-2 infects several animal species and SARS-CoV-2 variants of concern (VOCs) may even show (as in humans) enhanced inter- and intra-species transmission rates. We correlated sensitivity data of SARS-CoV-2 rapid antigen tests (RATs) to viral RNA genome equivalents analyzed by real-time reverse transcriptase-polymerase chain reaction (RT-PCR). Further, we checked their suitability for testing animals by assessing saliva and VOC effects. Viral loads up to 2 logs (RNA copy number) under the hypothetical SARS-CoV-2 infectivity threshold were detected by most analyzed RATs. However, while saliva from various animal species showed generally no adverse effects on the RATs' analytical sensitivities, the detection of VOCs B.1.1.7 and B.1.351 was in some RATs inferior to non-VOC viruses.


Assuntos
Antígenos Virais/isolamento & purificação , Teste Sorológico para COVID-19/veterinária , COVID-19/veterinária , Variação Genética , SARS-CoV-2/isolamento & purificação , Saliva/virologia , Animais , COVID-19/diagnóstico , COVID-19/virologia , Teste Sorológico para COVID-19/normas , Chlorocebus aethiops , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/veterinária , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Células Vero , Carga Viral/veterinária
13.
Protein Expr Purif ; 188: 105965, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34461217

RESUMO

BACKGROUND: Egypt has a high prevalence of hepatitis C virus (HCV) infection with 92.5% of genotype-4. AIM: This study aimed to clone and express the core gene of HCV genotype-4 for using it to develop a highly sensitive, specific, and cost-effective diagnostic assay for detecting HCV infection. METHODS: Using synthetic HCV genotype-4 core gene, pET15b as E. coli expression vector, and 1 mM lactose as inducer, the HCV core protein (MW 17 kDa) was expressed in the form of inclusion bodies (IBs) that was purified and solubilized using 8 M guanidinium HCl. The recombinant core protein was in vitro refolded by a rapid dilution method for further purification using weak cation exchange liquid chromatography. The immunogenicity of the purified protein was tested by ELISA using 129 serum samples. RESULTS: The recombinant core protein was successfully expressed and purified. The results also showed that the in-house anti-HCV core assay is accurate, specific (~96.6%), and highly sensitive (~100%) in accordance with the commercial ELISA kit. CONCLUSION: The sensitivity, specificity, and reproducibility of the developed assay were high and promising to be used as a screening assay for detecting HCV infection.


Assuntos
Anticorpos Antivirais/sangue , Antígenos Virais/genética , Hepacivirus/genética , Hepatite C/diagnóstico , Proteínas do Core Viral/genética , Antígenos Virais/biossíntese , Antígenos Virais/imunologia , Antígenos Virais/isolamento & purificação , Cromatografia por Troca Iônica/métodos , Clonagem Molecular , Egito/epidemiologia , Ensaio de Imunoadsorção Enzimática , Escherichia coli/genética , Escherichia coli/metabolismo , Expressão Gênica , Vetores Genéticos/química , Vetores Genéticos/metabolismo , Genótipo , Guanidina/química , Hepacivirus/classificação , Hepacivirus/imunologia , Hepatite C/epidemiologia , Hepatite C/virologia , Humanos , Soros Imunes/química , Corpos de Inclusão/química , Prevalência , Redobramento de Proteína , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/genética , Proteínas Recombinantes/imunologia , Proteínas Recombinantes/isolamento & purificação , Proteínas do Core Viral/biossíntese , Proteínas do Core Viral/imunologia , Proteínas do Core Viral/isolamento & purificação
14.
J Infect Dis ; 224(4): 616-619, 2021 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-34398244

RESUMO

Emerging severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants may influence the effectiveness of existing laboratory diagnostics. In the current study we determined whether the British (20I/501Y.V1) and South African (20H/501Y.V2) SARS-CoV-2 variants of concern are detected with an in-house S1-based antigen detection assay, analyzing spiked pools of quantitative reverse-transcription polymerase chain reaction-negative nasopharyngeal swab specimens. The assay, combining 4 monoclonal antibodies, allowed sensitive detection of both the wild type and the variants of concern, despite accumulation of several mutations in the variants' S1 region-results suggesting that this combination, targeting distinct epitopes, enables both specificity and the universality.


Assuntos
COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/classificação , Anticorpos Monoclonais/imunologia , Antígenos Virais/imunologia , Antígenos Virais/isolamento & purificação , COVID-19/imunologia , Humanos , Mutação , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Glicoproteína da Espícula de Coronavírus/genética , Glicoproteína da Espícula de Coronavírus/isolamento & purificação , Carga Viral
15.
Diagn Microbiol Infect Dis ; 101(4): 115490, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34399380

RESUMO

RT-PCR is the gold standard to detect SARS-CoV-2, however, its capacity is limited. We evaluated an automated antigen detection (AAD) test, Elecsys SARS-CoV-2 Antigen (Roche, Germany), for detecting SARS-CoV-2. We compared the limit of detection (LOD) between AAD test, rapid antigen detection (RAD) test; SARS-CoV-2 Rapid Antigen Test (SD Biosensor, Korea), and in-house RT-PCR test. LOD results showed that the AAD test was 100 fold more sensitive than the RAD test, while the sensitivity of the AAD test was comparable to the RT-PCR test. The AAD test detected between 85.7% and 88.6% of RT-PCR-positive specimens collected from COVID-19 patients, false negative results were observed for specimens with Ct values >30. Although clinical sensitivity for the AAD test was not superior or comparable to the RT-PCR test in the present study, the AAD test may be an alternative to RT-PCR test in terms of turn-around time and throughput.


Assuntos
Antígenos Virais/isolamento & purificação , Teste Sorológico para COVID-19/métodos , COVID-19/virologia , Kit de Reagentes para Diagnóstico , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Teste de Ácido Nucleico para COVID-19 , Testes Diagnósticos de Rotina , Humanos , Limite de Detecção , Sensibilidade e Especificidade , Carga Viral
16.
Biotechnol Bioeng ; 118(11): 4317-4330, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34297405

RESUMO

Pathogen surface antigens are at the forefront of the viral strategy when invading host organisms. These antigens, including membrane proteins (MPs), are broadly targeted by the host immune response. Obtaining these MPs in a soluble and stable form constitutes a real challenge, regardless of the application purposes (e.g. quantification/characterization assays, diagnosis, and preventive and curative strategies). A rapid process to obtain a native-like antigen by solubilization of a full-length MP directly from a pathogen is reported herein. Rabies virus (RABV) was used as a model for this demonstration and its full-length G glycoprotein (RABV-G) was stabilized with amphipathic polymers, named amphipols (APols). The stability of RABV-G trapped in APol A8-35 (RABV-G/A8-35) was evaluated under different stress conditions (temperature, agitation, and light exposure). RABV-G/A8-35 in liquid form exhibited higher unfolding temperature (+6°C) than in detergent and was demonstrated to be antigenically stable over 1 month at 5°C and 25°C. Kinetic modeling of antigenicity data predicted antigenic stability of RABV-G/A8-35 in a solution of up to 1 year at 5°C. The RABV-G/A8-35 complex formulated in an optimized buffer composition and subsequently freeze-dried displayed long-term stability for 2-years at 5, 25, and 37°C. This study reports for the first time that a natural full-length MP extracted from a virus, complexed to APols and subsequently freeze-dried, displayed long-term antigenic stability, without requiring storage under refrigerated conditions.


Assuntos
Antígenos Virais/química , Antígenos Virais/isolamento & purificação , Detergentes/química , Vírus da Raiva/química , Proteínas do Envelope Viral/química , Proteínas do Envelope Viral/isolamento & purificação , Liofilização , Estabilidade Proteica
17.
J Microbiol Immunol Infect ; 54(5): 776-786, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34272205

RESUMO

Making the correct diagnosis of a patient seeking medical attention is the ultimate goal of a practicing physician, irrespective of whether the cause of the patient's condition is infectious or non-infectious. Antigen detection tests can be used to aid in the diagnosis of various infectious-related disorders including COVID-19 where it has become especially important due to the serious nature of this disease and its worldwide prevalence. These tests closely mimic one of the earliest prototypes - the urine pregnancy test - and as a result they have gained wide acceptance based on their overall simplicity, low cost and relative accuracy. In some situations, especially as a screening test, they can be used instead of the more technically demanding and complex molecular and serologic assays that are still useful and helpful under many different circumstances. Antigen detection systems are based on finding a particular immunogenic component, typically a protein or polysaccharide molecule, that is both unique and an integral part of the pathogen or other biological entity. Because these tests generally provide only qualitative results, they often need to be supplemented with other and sometimes more sophisticated laboratory-based diagnostic procedures to corroborate the initial test result. In this review, we first describe general background information on antigen-detection methods, including any unique aspects of their overall design, and then follow with an extensive description on the merits and limitations of these tests for detecting COVID-19 and, to a lesser extent, for other serious respiratory diseases caused by three common bacterial pathogens - Streptococcus pyogenes, Streptococcus pneumoniae and Legionella pneumophila.


Assuntos
Antígenos Virais/isolamento & purificação , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Doenças Transmissíveis/diagnóstico , Testes Imunológicos/métodos , SARS-CoV-2/isolamento & purificação , Doenças Transmissíveis/microbiologia , Doenças Transmissíveis/virologia , Testes Diagnósticos de Rotina , Feminino , Humanos , Legionella pneumophila , Gravidez , Streptococcus pneumoniae , Streptococcus pyogenes
18.
Clin Microbiol Infect ; 27(11): 1700.e1-1700.e3, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34325065

RESUMO

OBJECTIVES: The aim was to assess the performance of antigen-based rapid diagnostic tests (Ag-RDTs) for SARS CoV-2 when implemented for large-scale universal screening of asymptomatic individuals. METHODS: This study was a pragmatic implementation study for universal Ag-RDT-based screening at a tertiary care hospital in Germany where patients presenting for elective procedures and selected personnel without symptoms suggestive of SARS-CoV-2 were screened with an Ag-RDT since October 2020. Test performance was calculated on an individual patient level. RESULTS: In total, 49 542 RDTs were performed in 27 421 asymptomatic individuals over a duration of 5 and a half months. Out of 222 positive results, 196 underwent in-house confirmatory testing with PCR, out of which 170 were confirmed positive, indicating a positive predictive value of 86.7% (95% CI 81.2-91.1%). Negative Ag-RDTs were not routinely tested with PCR, but a total of 94 cases of false negative Ag-RDTs were detected due to PCR tests being performed within the following 5 days with a median cycle threshold value of 33 (IQR 29-35). DISCUSSION: This study provides evidence that Ag-RDTs can have a high diagnostic yield for transmission relevant infections with limited false positives when utilized at the point of care on asymptomatic patients and thus can be a suitable public health test for universal screening.


Assuntos
Antígenos Virais/isolamento & purificação , COVID-19 , Programas de Rastreamento/métodos , SARS-CoV-2 , COVID-19/diagnóstico , Teste para COVID-19/métodos , Testes Diagnósticos de Rotina , Alemanha , Humanos , Valor Preditivo dos Testes , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Atenção Terciária à Saúde
19.
BMC Infect Dis ; 21(1): 614, 2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34182936

RESUMO

BACKGROUND: Despite the global roll-out of rotavirus vaccines (RotaTeq/Rotarix / ROTAVAC/Rotasiil), mortality and morbidity due to group A rotavirus (RVA) remains high in sub-Saharan Africa, causing 104,000 deaths and 600,000 hospitalizations yearly. In Cameroon, Rotarix™ was introduced in March 2014, but, routine laboratory diagnosis of rotavirus infection is not yet a common practice, and vaccine effectiveness studies to determine the impact of vaccine introduction have not been done. Thus, studies examining RVA prevalence post vaccine introduction are needed. The study aim was to determine RVA prevalence in severe diarrhoea cases in Littoral region, Cameroon and investigate the role of other diarrheagenic pathogens in RVA-positive cases. METHODS: We carried out a study among hospitalized children < 5 years of age, presenting with acute gastroenteritis in selected hospitals of the Littoral region of Cameroon, from May 2015 to April 2016. Diarrheic stool samples and socio-demographic data including immunization and breastfeeding status were collected from these participating children. Samples were screened by ELISA (ProSpecT™ Rotavirus) for detection of RVA antigen and by gel-based RT-PCR for detection of the VP6 gene. Co-infection was assessed by multiplexed molecular detection of diarrheal pathogens using the Luminex xTAG GPP assay. RESULTS: The ELISA assay detected RVA antigen in 54.6% (71/130) of specimens, with 45, positive by VP6 RT-PCR and 54, positive using Luminex xTAG GPP. Luminex GPP was able to detect all 45 VP6 RT-PCR positive samples. Co-infections were found in 63.0% (34/54) of Luminex positive RVA infections, with Shigella (35.3%; 12/34) and ETEC (29.4%; 10/34) detected frequently. Of the 71 ELISA positive RVA cases, 57.8% (41/71) were fully vaccinated, receiving two doses of Rotarix. CONCLUSION: This study provides insight on RVA prevalence in Cameroon, which could be useful for post-vaccine epidemiological studies, highlights higher than expected RVA prevalence in vaccinated children hospitalized for diarrhoea and provides the trend of RVA co-infection with other enteric pathogens. RVA genotyping is needed to determine circulating rotavirus genotypes in Cameroon, including those causing disease in vaccinated children.


Assuntos
Antígenos Virais/isolamento & purificação , Proteínas do Capsídeo/isolamento & purificação , Coinfecção/epidemiologia , Diarreia/virologia , Infecções por Rotavirus/epidemiologia , Rotavirus/genética , Bioensaio , Camarões/epidemiologia , Criança Hospitalizada , Pré-Escolar , Coinfecção/diagnóstico , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Lactente , Masculino , Prevalência , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Infecções por Rotavirus/diagnóstico , Infecções por Rotavirus/tratamento farmacológico , Vacinas contra Rotavirus/uso terapêutico , Vacinação , Vacinas Atenuadas/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...